■ Dr. Jordan Design
Calibration Service · IEC 60942

Sound Level Calibrator Calibration (Factory & DAkkS)

Verification of sound level calibrators of all brands (Brüel & Kjær, NTi, Norsonic, Svantek, Center, Bedrock) for SPL (94 / 114 dB), frequency (1,000 Hz), and distortion (THD).

  • For all Class 1 and Class 2 acoustic calibrators (1/2 inch and 1 inch)
  • Available as in-house ISO 9001 factory calibration or accredited DAkkS calibration
  • Exact measurement of sound pressure level, frequency stability, and THD per IEC 60942

Available Versions & Services

Current prices from Dresden stock / lab
Recommended
Recommended · ISO 9001 Factory Calibration
Calibration Service

Calibration Service

In-house verification of level, frequency, and THD incl. traceable factory calibration certificate.

59,50 € incl. 19% VAT
50,00 € net plus shipping
Official Audits · DAkkS (ISO 17025)
DAKKS Kalibrierung für Schallpegelkalibratoren und Pistonphone

DAKKS Kalibrierung für Schallpegelkalibratoren und Pistonphone

Accredited DAkkS calibration per DIN EN ISO/IEC 17025 for sound calibrators and pistonphones.

415,31 € incl. 19% VAT
349,00 € net plus shipping
Repair & Adjustment · Center 326
Sound level calibrator Center 326 repair service

Sound level calibrator Center 326 repair service

Repair and adjustment service for out-of-spec or defective Center 326 and identical calibrators.

115,00 € incl. 19% VAT
96,64 € net plus shipping
Workflow

3-Step Procedure

Step 1

1. Choose Calibration Type

Select either our ISO 9001 factory calibration (S101) or accredited DAkkS calibration (DAKKS-CAL).

Step 2

2. Ship Calibrator

Send your calibrator securely packaged to our Dresden laboratory.

Step 3

3. Certificate & Return

Receive your calibrator back with its new test certificate and calibration label.

What We Measure During Sound Calibrator Verification per IEC 60942

Click to expand technical details and standard references

A sound level calibrator is the reference standard of your entire measurement chain. If the calibrator drifts by 1.5 dB, you transfer that exact error onto your sound level meter during every field check. According to IEC 60942, sound pressure level tolerances are strictly limited for Class 1 and Class 2 devices.

In our Dresden laboratory, we verify not only the acoustic output at 94.0 dB (1 Pa) and 114.0 dB (10 Pa), but also measure exact frequency stability (1,000 Hz) and total harmonic distortion (THD) on our Audio Precision APx555. For out-of-spec Center 326 units, we also offer direct internal feedback loop readjustment (Art. 7002RS).

Dokumenten-ID: DJD-QM-TRACE-2026 | Rev. 2.2

Declaration of Metrological Traceability & Test Equipment Monitoring

Note on Division of Services (Factory vs. DAkkS Calibration): All traceable factory calibrations are performed directly in-house at our Dresden laboratory following the cascaded hierarchy documented below. Whenever an accredited DAkkS calibration per DIN EN ISO/IEC 17025 is commissioned for regulatory purposes, it is executed through our external DAkkS-accredited partner laboratories.

Lab Reference Chain (IEC 61094-5)

How we calibrate each individual ECM8000 simultaneously

No guesswork, no sequential swapping: Every capsule is calibrated simultaneously inside our symmetric Spectra SQ-4.2 pressure chamber against a traceable €50,000+ Class-1 reference chain. Click components for technical details.

📋 Full Lab Dossier & Comparison →