DIN 4109 · ISO 16283-1/-2 · ISO 717 · All Systems Traceable & DAkkS-Calibratable

Measure Building Acoustics, Airborne & Impact Sound: From Noise-Immune Chirp Systems to Ultra-Compact Active Dodecahedrons

For standard-compliant verification of sound insulation in buildings per DIN 4109, ISO 16283, and ISO 717 (weighted sound reduction index R'w, standardized level difference DnT,w, and impact sound pressure level L'n,w), you no longer need to haul heavy 1,600-watt amplifier racks to the job site. Thanks to modern Chirp cross-correlation per ISO 18233 (up to +54 dB processing gain against background noise) and ultra-compact active sound sources, field effort is drastically reduced—with full traceability and DAkkS calibration capability across all components.

Detailed theoretical fundamentals, sound reduction indices, and interactive simulations for airborne sound can be found in our specialized guide Airborne Building Acoustics.

Choose Your Entry Point into Our Building Acoustics Portfolio (System Purchase, Reporter Software, Sound Sources & Weekly Rental):
Path 1 · HERO: Akulap Modular & Chirp

Akulap Base + Building + RT60 + Mic + Calibrator

Our modular PC system combining Akulap Base + Building Acoustics Module + RT60 Module (software core total 3050,00 € Net (3629,50 € incl. 19% VAT)) plus 1/2" Class 1 microphone and calibrator. Supports both classical noise and noise-immune Chirp.
Path 2 · Evaluation & Device Control

Standalone Reporter & Control Package

Looking for a standalone software package for standard-compliant calculation and reporting that can also directly control measurement instruments? Our Akulap Building Acoustics Reporter calculates all single-number ratings and generates complete reports.
Path 3 · Standalone Handhelds

Bedrock SM50, SM90 & AM100 (Building Acoustics Included!)

No expensive add-on licenses like NTi or Svantek: In the Bedrock SM50, Class 1 Bedrock SM90, and Bedrock AM100, airborne, impact, and RT60 measurements per ISO 16283 / ISO 3382 are included out of the box.
Path 4 · Compact Sound Sources

LookLine Active Dodecahedron (Amp Built-In!) & Tapping Machines

Job-site highlight: The ultra-compact LookLine active dodecahedron integrates the power amplifier directly inside the sphere—no heavy amp rack required! Plus passive dodecahedrons, 700W amplifiers, and tapping machines.
Path 5 · Weekly Rental & DAkkS

Building Acoustics Rental Kit (100% Credit) & DAkkS Service

Single project or field evaluation? Rent dodecahedrons, power amplifiers, tapping machines, or Class 1 measurement kits by the week with 100% credit towards purchase.
Weekly Rental Instead of Blind Purchase · 100% Rental Credit Upon Purchase

Rent Building Acoustics Equipment: Dodecahedron, Tapping Machine & Class 1 Measurement Chain by the Week

Have an upcoming sound insulation acceptance test per DIN 4109 / ISO 16283, or want to test our sound sources and software under real job-site conditions first? In our equipment rental program, you can assemble the exact building acoustics components you need for 1 week—with 100% of the rental fee credited towards a subsequent purchase:

Rental Set 1 · Airborne Sound & RT60 (Source Room)

Rent Dodecahedron + Power Amplifier + Tripod

The complete omnidirectional source room setup per ISO 16283-1 and ISO 3382: Includes the 12-driver dodecahedron (220,00 € Net (261,80 € incl. 19% VAT)/week), matching power amplifier (49,00 € Net (58,31 € incl. 19% VAT)/week), and heavy-duty tripod (30,00 € Net (35,70 € incl. 19% VAT)/week)—complete set for 299,00 € Net (355,81 € incl. 19% VAT) per week.
Rental Set 2 · Impact Sound Insulation (Floors & Stairs)

Rent Tapping Machine per ISO 140 / ISO 16283-2

For standard-compliant determination of weighted impact sound pressure level L'n,w on floors and stairs, a calibrated 5-hammer tapping machine is mandatory. Rent our standard tapping machine for 350,00 € Net (416,50 € incl. 19% VAT) per week—or combine dodecahedron, amplifier, and tapping machine for 619,00 € Net (736,61 € incl. 19% VAT) total.
Rental Set 3 · Class 1 Receiving Chain & Calibrator

Rent Class 1 Measurement Kit, USB Microphone & Calibrator

Frequently Asked Practical Questions · Building Acoustics & Verification

Field FAQ: Airborne Sound, Impact Sound & Testing per ISO 16283 & DIN 4109

Why is the Chirp measurement method per ISO 18233 superior to interrupted noise? ▼
Sine-sweep excitation (Chirp) with synchronous cross-correlation per ISO 18233 achieves up to +54 dB processing gain over conventional pink noise. This means that even in environments with heavy job-site or street noise, the system yields high-precision sound reduction curves without hauling 1,600-watt amplifier racks or deafening noise levels. In addition, ultra-compact and lighter sources such as our LookLine active dodecahedron achieve identical or superior results.
Which standards and single-number quantities govern building compliance testing? ▼
Sound insulation requirements for building compliance are governed by DIN 4109. Field measurement procedures for airborne sound insulation follow ISO 16283-1 (apparent sound reduction index R'w and standardized level difference DnT,w), and for impact sound ISO 16283-2 (weighted normalized impact sound pressure level L'n,w and standardized impact level L'nT,w). Single-number ratings and spectrum adaptation terms (C, Ctr, CI) are computed in strict accordance with ISO 717-1 and ISO 717-2. All our software packages and report generators support this complete suite of standards.
Is a standardized tapping machine strictly required for impact sound testing on floors and stairs? ▼
Yes. DIN 4109 and ISO 16283-2 strictly mandate a standardized tapping machine featuring 5 hammers (500 g mass each, 40 mm free fall, 10 impacts per second) for normative compliance. Alternative excitation methods (e.g. rubber ball) are informative supplements only and do not replace legal verification. Our standard tapping machine #700200 meets all ISO 140 / ISO 16283-2 specifications and is available as a new unit, discounted demo device, or weekly rental kit.
How does the 100% rental credit towards a purchase work for building acoustics equipment? ▼
If you have an upcoming project or wish to evaluate equipment under real site conditions, you can rent the desired kit (e.g. dodecahedron source kit, tapping machine, or Class 1 receiving chain) for one or more weeks. If you decide to purchase the equipment or an equivalent new/demo system within 30 days of the rental period, 100% of the net rental fee is deducted directly from the purchase price.
Can measurement microphones and calibrators be delivered with a DAkkS calibration certificate? ▼
Yes. All our hardware instruments are shipped with traceable factory calibration certificates. For official audits, expert witness testimonies, and accredited testing labs, we offer complete DAkkS calibration services per DIN EN ISO/IEC 17025 in cooperation with accredited partner calibration laboratories for sound level calibrators (Class 1 and Class 2) and pre-checks for 1/2" measurement microphones and sound meters.