Measure Building Acoustics & Airborne Sound Insulation to Standard
From shell construction to building sign-off: Apparent sound reduction index R', single-number R'w, spectrum adaptation terms C and Ctr, and the revolutionary swept-sine chirp method for high-performance sound insulation up to 80 dB.
The Measurement Principle of ISO 16283-1
Interactive cross-section: Source room, partition with flanking paths, and receiving room with reverberation time correction.
The sound reduction index R' accounts for source level L1, receiver level L2, partition area S, and equivalent absorption area A of the receiving room (derived from volume V2 and reverberation time T2 per Sabine).
1. Source Room (V1)
An omnidirectional dodecahedron loudspeaker creates a diffuse, high-level sound field (L1 approx. 100 dB). At least 5 microphone positions or a continuous spatial sweep capture the spatial average level.
The Classic Noise Method in Listening Comparison
Switch between source level L1 and receiver level L2. Watch the 1/3-octave RTA show how the partition absorbs high frequencies while low frequencies pass through.
Info: Source room: Uniform energy distribution across all 1/3-octave bands (Pink noise, -3 dB/oct energy slope = constant energy per fraction band).
The Single-Number Rating Trap: Why 52 dB ≠ 52 dB
Two partitions with identical weighted sound reduction R'w = 52 dB sound drastically different in practice. Listen to the direct A/B comparison!
Wall A: Heavy Solid Masonry Wall
Follows the theoretical mass law (+6 dB per octave). High attenuation already at 100 to 250 Hz. Male speech fundamentals and music bass are solidly subdued.
Wall B: Lightweight Drywall with Resonance Dip
Outstanding insulation at 1 kHz to 4 kHz, but deep coincidence and cavity resonance dip at 125–200 Hz. Mathematically compensated in R'w – but low voices rumble right through!
To prevent misjudgments from single-number R'w alone, ISO 717-1 defines spectrum adaptation terms: C for broadband noise (living activities, speech, high-speed rail) and Ctr for low-frequency dominated sources (urban road traffic, disco bass, near-ground aircraft).
Limits of Pink Noise & the Swept-Sine Chirp Method
Why measuring 75 to 80 dB sound insulation with noise becomes physically impossible – and how Akulap achieves the breakthrough using swept-sine deconvolution.
The Solution: Swept-Sine (Chirp) per ISO 18233
With the Akulap Building Acoustics Chirp Module, insulation is not measured with continuous noise, but via a frequency-modulated sine sweep followed by deconvolution into the room impulse response.
Mathematical energy compression of deconvolution enables 80 dB sound insulation measurements with modest 95 dB source levels!
Non-linear harmonic distortion of the loudspeaker falls into the negative time window of the impulse response, leaving the measurement pristine.
Uncorrelated construction noise (footsteps, hammering, traffic) cancels out almost completely during cross-correlation.
Handheld Meters vs. Akulap PC System
Choose the optimal tool for your workflow: Quick on-site checks with Bedrock handhelds or high-end swept-sine with Akulap.
compact STIPA Instrument IEC60268-16 ED4.0+ED5.0 Bedrock SM50
Autarker Handheld-Schallpegelmesser für schnelle Bauakustik-Messungen vor Ort. Integrierte Terzanalyse & RT60 Nachhallzeit.
compact STIPA Instrument IEC60268-16 ED5.0 class 1
Präzisions-Klasse-1-Messgerät nach IEC 61672-1 für behördliche Gutachten und gerichtsfeste Bauabnahmen nach DIN 4109.
AkuLap module building acoustics ISO 140/ 717, ISO/DIN 16283-1
Modulares PC-Messsystem mit 2-Kanal IEPE-Interface und Swept-Sine Dekonvolution für anspruchsvolle Schalldämmungen bis 80 dB.
Configure Your Building Acoustics Measurement System
Select measurement platform, sensor interface, and calibration. All pricing calculated transparently net and gross per PAngV.
Your Configuration
Rent Building Acoustics Equipment
Rent turnkey, pre-calibrated measurement equipment on a weekly basis for expert assessments, building sign-offs, or research.
Bedrock SM50 Building Acoustics Kit (Rental)
Standalone Class 2 sound level meter with building acoustics license, RTA, and reverberation testing. Pre-calibrated in heavy-duty flight case.
Akulap USB Measurement System Commercial (Rental)
Complete USB audio measurement system for noise, building, and room acoustics with Akulap software for Windows laptops.
Acoustic Metrics Overview
The most important building acoustic parameters per ISO 16283-1 and ISO 717-1 explained clearly.
R' (Apparent Sound Reduction Index)
Frequency-dependent measure of sound reduction of a partition in a real building including all flanking paths. Unit: Decibels (dB).
R'w (Weighted Apparent Sound Reduction Index)
Single-number rating per ISO 717-1, obtained by shifting a standardized reference curve against measured 1/3-octaves (100–3150 Hz) until unfavorable deviations total at most 32 dB.
D_nT,w (Weighted Standardized Level Difference)
Level difference between source and receiving rooms, normalized to a reference reverberation time T0 = 0.5 s in the receiving room. Common criterion for residential dwellings.
C & Ctr (Spectrum Adaptation Terms)
Correction values per ISO 717-1 for specific noise spectra. C addresses broadband living and speech noise; Ctr addresses low-frequency traffic and club music.
A (Equivalent Sound Absorption Area)
Calculated per Sabine: A = 0.16 · V2 / T2 (in m²). Normalizes the receiving room's acoustic reverberation effect on measured sound pressure L2.
ISO 18233 (Modern Measurement Methods)
International standard governing swept-sine and MLS techniques in building and room acoustics. Yields extreme noise rejection and up to 30 dB higher dynamic range than noise.
Häufig gestellte Fragen zur Bauakustik
What is the fundamental difference between R and R'? ▼
Sound reduction index R is measured in a laboratory test suite where flanking paths are suppressed by decoupled, massive structures (pure direct partition transmission). Apparent sound reduction R' is measured in situ in real buildings and encompasses all flanking transmissions via ceilings, floors, and adjoining walls.
Why does the single-number rating R'w often lead to noise complaints? ▼
The single-number rating R'w condenses a complex frequency curve into one figure. A lightweight wall with a resonance dip at 125 Hz can achieve the exact same 52 dB rating as a massive brick wall. However, at low frequencies (male voices, subwoofers, traffic), insulation is up to 15 dB worse. Hence spectrum adaptation terms C and Ctr are essential.
Why does pink noise fail for sound insulation above 75 dB? ▼
To maintain the mandatory 10 dB SNR against 35 dB background noise in the receiver room, receiving level L2 must reach 45 dB. For an 80 dB partition, this requires 125 to 128 dB continuous source level. No commercial dodecahedron loudspeaker can sustain this power without thermal destruction or severe distortion.
How does the ISO 18233 swept-sine chirp method solve this? ▼
Instead of stochastic noise, a deterministic logarithmic sine sweep (chirp) is excited. Deconvolution compresses the energy of the full sweep into a concentrated impulse response. This yields a 20 to 30 dB SNR gain, isolates harmonic distortion into the non-causal time domain, and enables 80 dB measurements with modest 95 dB source levels.
When is a Bedrock handheld recommended versus the Akulap PC system? ▼
Bedrock SM50/SM90 handhelds are unmatched for rapid routine sign-offs, room acoustics (RT60), and partitions up to approx. 65 dB. The Akulap PC system is recommended for demanding acoustic forensics, high-performance double walls, studios, test benches, ISO 18233 swept-sine workflows, and time-saving 2-channel parallel measurement.
Why must reverberation time T2 be measured in the receiving room? ▼
The measured sound pressure L2 depends heavily on room absorption. In an empty room with tiles and concrete, reflections build up a much higher level than in a carpeted room. Reverberation correction A = 0.16 · V2 / T2 normalizes the result, making it independent of room furnishings.
Measure Building Acoustics, Airborne & Impact Sound: Complete Product & Rental Selector
Need tapping machines for impact sound (L'n,w), active dodecahedrons, or weekly rental packages with 100% purchase credit? Explore our interactive selector.