Add Missing DIN 45680 Evaluation to Your NTi XL2 / XL3 · DIN 45680:1997 & DIN/TS 45610-1:2026-01

Already Own an NTi XL2 or XL3? How to Add the Missing DIN 45680 & DIN/TS 45610-1 Evaluation on Your PC

Many acoustic consultants, engineering firms, and environmental agencies already own an NTi Audio XL2 or XL3. However, when tasked with measuring low-frequency noise—such as from a heat pump, chiller, or HVAC system in a bedroom—users immediately face a major limitation: NTi Audio does not offer an evaluation module for DIN 45680 or the new DIN/TS 45610-1:2026-01, neither on the handheld meter nor in their PC software. Automated 1/3-octave hearing threshold comparison, standard-compliant pure-tone assessment, and a ready-to-use DIN 45680 test report are simply not available from NTi.

The solution without buying new hardware: Our PC laboratory system Akulap closes this exact gap for your existing NTi XL2 or XL3. Akulap directly imports the .wav recordings saved on your XL2's SD card (even the compressed 4-bit ADPCM files of the basic XL2 model without the expensive Extended Acoustic Pack), automatically extracting the hidden NTi calibration header. Akulap then calculates the complete 4-page test report per DIN 45680:1997 and DIN/TS 45610-1:2026-01—including the LCeq − LAeq criterion, hearing threshold comparison, pure-tone penalties, and high-resolution FFT analysis to separate 50 Hz mains hum from compressor tones.

✓ Add Missing Module on PC

NTi does not offer a DIN 45680 module. Akulap fills this gap directly via your existing recordings.

✓ DIN 45680:1997 & DIN/TS 45610-1

Automated 4-page report with 1/3-octaves, hearing threshold comparison, and LCeq - LAeq criteria.

✓ Standard WAV & 4-Bit ADPCM

Works without Extended Acoustic Pack. Calibration factors are extracted automatically.

Video Demonstration (14:09 min) · Direct Calibration Header Import

Video Tutorial: Import Recorded .wav Files (e.g. from NTi XL2) into Akulap & Evaluate per DIN 45680

▶

By loading this video, you accept YouTube's privacy policy (youtube-nocookie.com).

Step-by-step tutorial: How Akulap extracts embedded calibration headers (dB offset, serial number) from NTi XL2 audio WAVs (incl. 4-bit ADPCM) and automatically generates a compliant DIN 45680 / DIN/TS 45610-1 test report.

Direct Video Chapters:

Critical Physical Limit · Thermal Capsule Self-Noise

The 1/4-Inch Trap on the NTi XL2 (e.g. M4261): When Microphone Self-Noise Exceeds the DIN 45680 Hearing Threshold

Even the best evaluation software cannot help if the attached microphone capsule has higher self-noise at low frequencies than the hum in the bedroom. Using a 1/4-inch microphone on the NTi XL2 often measures only thermal capsule noise in low 1/3-octave bands. In our microphone capsule selection guide and low-noise microphone overview, we explain why DIN 45680 requires at least a 1/2-inch Class 1 capsule (directly on the XL2 via 48V XLR or as a standalone USB system).

Capsule Type & Size Typical Self-Noise Low 1/3-Octave Behavior (8–100 Hz) Suitability for DIN 45680 / Bedroom
1/4" Class 2 Capsule (e.g. NTi M4261) approx. 27 – 32 dB(A) Critical: At 16–31.5 Hz, capsule noise often exceeds the DIN 45680 hearing threshold ❌ Unsuitable for quiet bedrooms (measures its own noise)
1/2" Class 1 Capsule (e.g. NTi M2230, 48V XLR or ATD5-T USB) approx. 14 – 16 dB(A) Clean SNR across relevant 1/3-octave bands for heat pumps & HVAC ✅ Practical standard for DIN 45680 & TA Lärm
1/2" / 1" Ultra-Low-Noise Special Mic (Microtech Gefell MMS214) 5.5 – 6.5 dB(A) Maximum physical resolution down to 1 Hz per DIN/TS 45610-1 🏆 Lab reference for infrasound & ultra-quiet rooms

Recommended Class 1 sensors for low frequencies & infrasound:

Dynamic System & Price Overview (100% Live from Product Database)

3 Paths to DIN 45680 Evaluation: Why Almost All XL2 Users Choose the +80,00 € Upgrade

Path A · Pure Post-Processing

Akulap .wav Analysis + DIN 45680 Module

Included components:
• AkuLap .wav file analysis viewer: 670,00 € Net
• Akulap Modul DIN45680:1997 und DIN/TS 45610-1:2026-01: 1000,00 € Net
Package price: 1670,00 € Net
1987,30 € incl. 19% VAT

Replaces the Akulap base package: Combines Akulap .wav File Analysis with the DIN 45680 & DIN/TS 45610-1 Module. Ideal if you exclusively want to evaluate existing SD card recordings from your NTi XL2 or XL3 on your PC.

Request / Order Path A →
★ RECOMMENDED ★
Path B · Recommended (Only +80,00 € Net Difference!)

Akulap Base (Live + WAV) + DIN 45680 Module

Included components:
• Akulap module sound and noise: 750,00 € Net
• Akulap Modul DIN45680:1997 und DIN/TS 45610-1:2026-01: 1000,00 € Net
Complete system: 1750,00 € Net
2082,50 € incl. 19% VAT
➔ Only 80,00 € Net more than Path A!

For a minimal difference of just 80,00 € Net (95,20 € incl. 19% VAT), you get the full Akulap Base Version (Sound / Noise) instead of file-only analysis. Your practical advantage: Simply plug in a USB measurement microphone and a sound calibrator to measure all TA Lärm parameters live on your laptop—keeping your expensive NTi XL2 free for other job sites!

Request / Order Path B (Recommended) →
Path C · 1-Week Field Test (100% Purchase Credit)

Use Existing DIN 45680 Rental Kit

Included components:
• EDU Rental Complete Audio Measurement System for environmental mesurements
• Incl. calibrated USB measurement microphone & software
1-week rental: 205,88 € Net / week
245,00 € incl. 19% VAT
➔ 100% credited toward purchase!

Via our DIN 45680 rental program, you get the complete Akulap evaluation software plus a calibrated plug-and-play USB microphone for 1 week. Evaluate your XL2 WAV files immediately—and discover in the field how much simpler direct measurement with Akulap and USB microphone is (100% rental credit upon purchase).

Request Rental Kit (100% Credit) →

Direct links to modules & systems in the B2B catalog:

Hardware Alternative Without License Surcharges · Bedrock SM50 / SM90

Don't Own an NTi XL2 Yet, or Need a Second Handheld Meter with All Options Included Out of the Box?

With the NTi XL2 and XL3, key functions such as uncompressed 24-bit WAV recording, 1/3-octave analysis, STIPA speech intelligibility, or room acoustics are paid add-on options. If you are planning a new purchase or need a second handheld analyzer for your office, the Bedrock SM50 offers a completely different approach: All measurement modules are factory-unlocked at no extra license cost—including uncompressed 24-bit / 48 kHz WAV recording for seamless DIN 45680 evaluation in Akulap.

Frequently Asked Engineering Questions · NTi XL2 & DIN 45680

Practical FAQ on Evaluating NTi XL2 / XL3 Data in Akulap

Why is the price difference between standalone Akulap .wav analysis and the full Akulap base version only 80,00 € Net? ▼
The mathematical DSP algorithms (FFT, IEC 61260 1/3-octave filter bank, calibration header decoder, and TA Lärm statistical evaluation) are identical in both versions. For just 80,00 € Net (95,20 € incl. 19% VAT) extra, the base version also unlocks live measurement via ASIO/USB, allowing you to connect a calibrated USB microphone and calibrator anytime to measure all TA Lärm parameters live.
Does NTi Audio offer its own module for DIN 45680 or DIN/TS 45610-1? ▼
No. Neither the handheld analyzer (XL2 / XL3) nor NTi's PC software includes automated evaluation per DIN 45680:1997 or DIN/TS 45610-1:2026-01. Akulap closes this gap by reading the XL2's recorded WAV files directly and generating the 4-page standard test report automatically.
Do I need to buy NTi's expensive 'Extended Acoustic Pack' to evaluate XL2 WAV files per DIN 45680 in Akulap? ▼
No. Even without add-on licenses, the NTi XL2 records audio files in 4-bit ADPCM format at a 24 kHz sampling rate (12 kHz bandwidth) including the calibration header. Because DIN 45680:1997 and DIN/TS 45610-1:2026-01 only evaluate low frequencies up to 100 Hz, the standard ADPCM format is completely sufficient and read directly by Akulap.