Already Own an NTi XL2 or XL3? How to Add the Missing DIN 45680 & DIN/TS 45610-1 Evaluation on Your PC
Many acoustic consultants, engineering firms, and environmental agencies already own an NTi Audio XL2 or XL3. However, when tasked with measuring low-frequency noise—such as from a heat pump, chiller, or HVAC system in a bedroom—users immediately face a major limitation: NTi Audio does not offer an evaluation module for DIN 45680 or the new DIN/TS 45610-1:2026-01, neither on the handheld meter nor in their PC software. Automated 1/3-octave hearing threshold comparison, standard-compliant pure-tone assessment, and a ready-to-use DIN 45680 test report are simply not available from NTi.
The solution without buying new hardware: Our PC laboratory system Akulap closes this exact gap for your existing NTi XL2 or XL3. Akulap directly imports the .wav recordings saved on your XL2's SD card (even the compressed 4-bit ADPCM files of the basic XL2 model without the expensive Extended Acoustic Pack), automatically extracting the hidden NTi calibration header. Akulap then calculates the complete 4-page test report per DIN 45680:1997 and DIN/TS 45610-1:2026-01—including the LCeq − LAeq criterion, hearing threshold comparison, pure-tone penalties, and high-resolution FFT analysis to separate 50 Hz mains hum from compressor tones.
NTi does not offer a DIN 45680 module. Akulap fills this gap directly via your existing recordings.
Automated 4-page report with 1/3-octaves, hearing threshold comparison, and LCeq - LAeq criteria.
Works without Extended Acoustic Pack. Calibration factors are extracted automatically.
Video Tutorial: Import Recorded .wav Files (e.g. from NTi XL2) into Akulap & Evaluate per DIN 45680
Step-by-step tutorial: How Akulap extracts embedded calibration headers (dB offset, serial number) from NTi XL2 audio WAVs (incl. 4-bit ADPCM) and automatically generates a compliant DIN 45680 / DIN/TS 45610-1 test report.
Direct Video Chapters:
The 1/4-Inch Trap on the NTi XL2 (e.g. M4261): When Microphone Self-Noise Exceeds the DIN 45680 Hearing Threshold
Even the best evaluation software cannot help if the attached microphone capsule has higher self-noise at low frequencies than the hum in the bedroom. Using a 1/4-inch microphone on the NTi XL2 often measures only thermal capsule noise in low 1/3-octave bands. In our microphone capsule selection guide and low-noise microphone overview, we explain why DIN 45680 requires at least a 1/2-inch Class 1 capsule (directly on the XL2 via 48V XLR or as a standalone USB system).
| Capsule Type & Size | Typical Self-Noise | Low 1/3-Octave Behavior (8–100 Hz) | Suitability for DIN 45680 / Bedroom |
|---|---|---|---|
| 1/4" Class 2 Capsule (e.g. NTi M4261) | approx. 27 – 32 dB(A) | Critical: At 16–31.5 Hz, capsule noise often exceeds the DIN 45680 hearing threshold | ❌ Unsuitable for quiet bedrooms (measures its own noise) |
| 1/2" Class 1 Capsule (e.g. NTi M2230, 48V XLR or ATD5-T USB) | approx. 14 – 16 dB(A) | Clean SNR across relevant 1/3-octave bands for heat pumps & HVAC | ✅ Practical standard for DIN 45680 & TA Lärm |
| 1/2" / 1" Ultra-Low-Noise Special Mic (Microtech Gefell MMS214) | 5.5 – 6.5 dB(A) | Maximum physical resolution down to 1 Hz per DIN/TS 45610-1 | 🏆 Lab reference for infrasound & ultra-quiet rooms |
Recommended Class 1 sensors for low frequencies & infrasound:
3 Paths to DIN 45680 Evaluation: Why Almost All XL2 Users Choose the +80,00 € Upgrade
Akulap .wav Analysis + DIN 45680 Module
• Akulap Modul DIN45680:1997 und DIN/TS 45610-1:2026-01: 1000,00 € Net
Replaces the Akulap base package: Combines Akulap .wav File Analysis with the DIN 45680 & DIN/TS 45610-1 Module. Ideal if you exclusively want to evaluate existing SD card recordings from your NTi XL2 or XL3 on your PC.
Akulap Base (Live + WAV) + DIN 45680 Module
• Akulap Modul DIN45680:1997 und DIN/TS 45610-1:2026-01: 1000,00 € Net
For a minimal difference of just 80,00 € Net (95,20 € incl. 19% VAT), you get the full Akulap Base Version (Sound / Noise) instead of file-only analysis. Your practical advantage: Simply plug in a USB measurement microphone and a sound calibrator to measure all TA Lärm parameters live on your laptop—keeping your expensive NTi XL2 free for other job sites!
Use Existing DIN 45680 Rental Kit
• Incl. calibrated USB measurement microphone & software
Via our DIN 45680 rental program, you get the complete Akulap evaluation software plus a calibrated plug-and-play USB microphone for 1 week. Evaluate your XL2 WAV files immediately—and discover in the field how much simpler direct measurement with Akulap and USB microphone is (100% rental credit upon purchase).
Direct links to modules & systems in the B2B catalog:
Don't Own an NTi XL2 Yet, or Need a Second Handheld Meter with All Options Included Out of the Box?
With the NTi XL2 and XL3, key functions such as uncompressed 24-bit WAV recording, 1/3-octave analysis, STIPA speech intelligibility, or room acoustics are paid add-on options. If you are planning a new purchase or need a second handheld analyzer for your office, the Bedrock SM50 offers a completely different approach: All measurement modules are factory-unlocked at no extra license cost—including uncompressed 24-bit / 48 kHz WAV recording for seamless DIN 45680 evaluation in Akulap.