HIGH-SPL METROLOGY · 140 dB TO 186 dB PEAK · AKULAP & MICROTECH GEFELL

Measuring High Sound Pressure Levels (140 dB to 186 dB): Signal Chain, Preamp Clipping & 1/4" Capsules

At extreme sound pressure levels beyond 140 dB SPL (200 Pa) up to 186 dB Peak (approx. 40,000 Pa / 0.4 bar)—such as occupational impulse noise, firearm and blast-wave testing, airbags, pyrotechnics, engine testbeds, or rocket propulsion—standard measurement systems fail immediately. In 90% of practical cases, however, it is not the microphone capsule that overloads first, but the microphone preamplifier (voltage clipping).

This engineering guide explains why classical 48 V XLR hand-held sound level meters (such as NTi XL2/XL3 or Bedrock SM50/SM90) hit electrical limits early, and how to measure distortion-free up to 186 dB using the Akulap Base System (incl. Class 1 SPL, real-time 1/3-octave & FFT), our high-headroom 10 Vrms USB frontends (ATD5-T & Microtech Gefell MV 240), and low-sensitivity 1/4" high-SPL capsules (3.5 mV/Pa down to 0.25 mV/Pa).

Introduction & Practical SPL Zones: Where Does High-SPL Begin?

ZONE 1 · 90 dB TO 130 dB 120 dB – 130 dB SPL (20 – 63 Pa)

Standard Metrology (Room, Building & Environmental)

Classical sound level meters and standard USB measurement microphones are designed for this range—fully sufficient for room acoustics, building acoustics, and normal environmental noise. Covered by standard 1/2" capsules (50 mV/Pa) and Akulap Base.

Recommended Capsule: 1/2" Standard (50 mV/Pa)
ZONE 2 · 130 dB TO 140 dB Up to 140 dB SPL / LCpeak (200 Pa = 10 Vrms!)

Occupational Safety & Industry (up to 140 dB · EU 2003/10/EC)

High-grade Class 1 sound level meters (e.g., for workplace impulse noise per LärmVibrationsArbSchV / EU 2003/10/EC, LC,peak up to 140 dB) cover this range with a standard 1/2" capsule (50 mV/Pa), provided the preamplifier delivers sufficient voltage swing (a full 10.0 Vrms / 28.28 Vpp headroom like our ATD5-T with Akulap Base).

Recommended Chain: 1/2" High-Dynamic (ATD5-T 10 Vrms)
ZONE 3 · > 140 dB TO 186 dB 140 dB – 186 dB Peak (200 Pa to 40,000 Pa)

Extreme High-SPL (> 140 dB to 186 dB · MIL-STD-1474E, Aerospace & Airbags)

For defense applications (firearms, acoustic trauma analysis, blast waves per MIL-STD-1474E), aerospace (rocket and jet engines), airbags, pyrotechnics, or engine test cells, standard measurement systems fail immediately. Here, specialized high-SPL signal chains using low-sensitivity 1/4" capsules (3.5 mV/Pa down to 0.25 mV/Pa) via Adapter A 67 on ATD5-T or MV 240 are mandatory.

Recommended Chain: 1/4" Capsule + Adapter A 67 + MV 240 / ATD5-T
SECTION 1.5 · DEFENSE, MILITARY, AEROSPACE & OCCUPATIONAL SAFETY STANDARDS

Key Military, Defense & Occupational Safety Standards for High-SPL (Executive Overview)

For government authorities, defense testing agencies (WTD), firearms and ammunition manufacturers, and occupational safety engineers, the following regulatory standards govern high-SPL testing and impose strict requirements on the measurement chain (capsule diameter, bandwidth, rise time, and preamplifier headroom):

Standard / Specification Application Scope Key Thresholds & SPL Ranges Measurement & Hardware Requirements (Why 1/4" + High Sample Rate?)
WORKPLACE SAFETY · UP TO 140 dB(C)
LärmVibrationsArbSchV / EU 2003/10/EC & ISO 9612
Civilian occupational health & industrial impulse noise • Lower action value: LC,peak = 135 dB(C) (112 Pa)
• Upper action value: LC,peak = 137 dB(C) (141 Pa)
• Max. exposure limit: LC,peak = 140 dB(C) (200 Pa)
Requires IEC 61672-1 Class 1 signal chain without preamplifier clipping at 140 dB (10 Vrms / 28.28 Vpp at 50 mV/Pa). Above 140 dB, a lower-sensitivity capsule is strictly required.
DEFENSE & BLAST · > 140 TO > 180 dB
MIL-STD-1474E
(US Dept. of Defense Design Criteria Standard – Noise Limits)
Military systems, small arms, artillery, armored vehicles, aviation & blast overpressure • Impulse noise from 140 dB Peak upward
• Weapon noise limits typ. 140 dB to 165 dB (with hearing protection) up to > 180 dB (Lpeak) for heavy artillery / muzzle brakes
• Evaluated via AHAAH model or LIAeq100ms (MIL-STD-1474E Appendix B)
Demands distortion-free capture of ultra-steep shockwave fronts (rise times < 5 µs to 20 µs):
• Zero phase or amplitude limiting (min. 100 kHz to 192 kHz sample rate recommended → Gefell MV 240 at 192 kHz)
• Small diaphragm (1/4" such as MK 301 E / MK 342 E) in grazing incidence (90°) to prevent pressure-doubling reflections.
NATO BALLISTICS · 150 TO 186 dB PEAK
NATO AEP-4785 (Successor to STANAG 4347) & TOP 01-2-608A
NATO standard for acoustic impulse testing of weapons, projectiles & explosives 150 dB to 186 dB Peak (Friedlander wave: peak overpressure Ppeak, A-duration tA, and B-duration tB) Requires uncompressed time-domain waveform recording (WAV/PCM without auto-gain or high-pass phase distortion below 1 Hz) to accurately integrate the shockwave pressure-time impulse.
AEROSPACE · 130 TO 165 dB CONTINUOUS
MIL-STD-810H (Method 515.8 – Acoustic Noise) & RTCA DO-160G
Aerospace, rocket engines, avionics vibro-acoustic testing in reverberation chambers / ducts Broadband continuous overall sound pressure level (OASPL) from 130 dB to 165 dB across 1/3-octave bands Requires true real-time 1/3-octave band analysis (IEC 61260) and FFT in Akulap Base paired with an ultra-low-THD capsule (MK 301 E / MK 341 E) over minutes to hours.
AUTOMOTIVE & AIRBAG · 145 TO 178 dB
AK-LV 01 / SAE J247 / ISO 10844
Automotive: In-cabin airbag deployment & pyrotechnics 145 dB to 178 dB Peak inside the vehicle cabin Combined measurement of high-frequency pyrotechnic impulse (1/4" capsule MK 301 E / MK 342 E) and low-frequency cabin pressure rise.
SIGNAL CHAIN PHYSICS · 4 STAGES FROM DIAPHRAGM TO FFT

The 4 Links of the High-SPL Signal Chain: Where Is the Real Bottleneck?

To capture sound pressure levels beyond 140 dB without error, you must never look at the microphone capsule datasheet in isolation—you must analyze the complete chain of 1. Microphone Capsule → 2. Preamplifier (Impedance Converter) → 3. A/D Converter (ADC) → 4. DSP Analysis Software (Akulap Base):

01 STAGE 1 · TRANSDUCER & DIAPHRAGM PHYSICS

The Microphone Capsule: Distortion Limit (3% THD) vs. Mechanical Destruction Limit

Maximum Output SPL (3% THD): The level at which non-linear diaphragm displacement and capacitance change relative to the backplate cause severe harmonic distortion (3% Total Harmonic Distortion at 1 kHz). Beyond this threshold, spectral and peak measurements are physically invalid.

Mechanical Destruction Limit: The significantly higher level at which the tensioned nickel diaphragm undergoes plastic deformation, slams into the backplate, or ruptures mechanically.
⚠️ Critical Engineering Note on Datasheet Comparisons:

Reputable manufacturers (such as Microtech Gefell or G.R.A.S.) strictly specify the maximum SPL at 3% THD (both RMS and Peak). Less rigorous vendors frequently advertise the mere mechanical survival limit of the capsule, at which point the electrical signal is already completely distorted. These two figures must never be equated!

02 STAGE 2 · THE TRUE BOTTLENECK (90% OF ALL FAILURES)

The True Weak Point: The Preamplifier (Voltage Clipping)

In 90% of all field failures, it is not the microphone capsule that overloads first, but the preamplifier! A standard 1/2" measurement capsule has a sensitivity of S = 50 mV/Pa:

• At 94 dB SPL (1 Pa), the capsule outputs exactly 50 mVrms (0.14 Vpp).
• At 134 dB SPL (100 Pa), it already outputs 5.0 Vrms (14.14 Vpp).
• At 140 dB SPL (200 Pa), it generates a massive 10.0 Vrms (28.28 Vpp)!
🔌 Why Standard Preamplifiers Hard-Clip Here:

Basic preamplifiers, 5 V USB microphones, and current-limited 48 V XLR hand-held sound level meters typically hard-clip the signal at just 2.0 Vrms to 3.5 Vrms—even if the capsule itself could mechanically handle 146 dB or 160 dB.

03 STAGE 3 · IN-HOUSING DUAL-RANGE DIGITIZATION

The A/D Converter (ADC) & 10 Vrms Dual-Range Architecture

The downstream A/D converter must digitize the preamplifier's high output voltage without clipping and without manual gain switching. Our USB reference frontends ATD5-T (10 Vrms / 28.3 Vpp input headroom with Dual-ADC) and Microtech Gefell MV 240 digital (24-bit Dual-Range Sigma-Delta ADC with 32-bit float recombination) process these high voltages directly inside the microphone body without lossy analog XLR cables.

Furthermore, the Microtech Gefell MV 240 features an internal, software-switchable 200 V polarization voltage generator and sample rates up to 192 kHz (80 kHz bandwidth) to resolve steep shockwave and blast fronts with full transient fidelity.
💎 Advantage Over Analog Signal Chains:

Zero ground loops, zero cable-capacitance roll-off at ultrasonic frequencies (up to 80 kHz), and zero overload of external audio interface inputs.

04 STAGE 4 · THE FUNNEL CORE: AKULAP BASE SYSTEM

Akulap Base System: Real-Time DSP, Class 1 SPL, 1/3-Octave, FFT & Automatic Scaling

All-Inclusive in the Base System: The Akulap Base System (#3303016) includes right out of the box the complete Class 1 sound level meter per IEC 61672-1 (LAeq, LCeq, LCpeak, LZpeak), real-time octave and 1/3-octave band analysis per IEC 61260, the high-resolution FFT spectrum analyzer, and uncompressed WAV recording—with zero hidden license fees for individual frequency bands.

Automatic High-SPL Scaling: When switching to low-sensitivity 1/4" capsules (3.5 mV/Pa down to 0.25 mV/Pa), Akulap seamlessly compensates the gain offset (ΔLcal up to +46.02 dB) via its calibration dialog. Optionally, Akulap can be expanded with Low-Frequency Noise Rating per DIN 45680 & DIN/TS 45610-1:2026-01 and Psychoacoustics (Zwicker Loudness in Sone per DIN 45631 / ISO 532-1).
🚀 No License Paywalls Like on Handheld Meters:

While traditional handheld meters often require expensive per-feature unlocks for 1/3-octave analysis, FFT, or WAV recording, Akulap Base delivers the complete laboratory analysis suite out of the box.

SYSTEM COMPARISON · XLR (P48) VS. ICP/IEPE VS. LEMO VS. AKULAP DUAL-ADC

System Comparison: Why Classical Hand-Held Sound Level Meters Hit Limits at Extreme SPL

Many engineers initially attempt to measure high sound pressure levels (> 135 dB to 180 dB) using existing hand-held meters and fail due to the electrical interface of the microphone preamplifier. The matrix below compares the 4 architectures:

Instrument Class & Examples Electrical Interface & Powering Why Is High-SPL Limited Here? Typical Voltage Limit High-SPL Rating (> 140 dB)
Hand-Held Sound Level Meters with XLR / P48
e.g., NTi Audio XL2, NTi XL3, Bedrock SM50, Bedrock SM90
Balanced XLR connector with 48 V phantom power (P48) 48 V phantom power is fed through two 6.8 kΩ resistors and is severely current-limited. Consequently, the impedance converter's internal supply rail sags early under large signal swings, and the analog XLR input stage restricts peak voltage headroom. approx. 2.5 Vrms to 5.0 Vrms (with standard capsule often limited to 130 – 138 dB) ⚠️ Limited

Ideal for room, building, and PA/VA acoustics, but electrically limited by the XLR/P48 interface during extreme impulses.

View Handheld Comparison →
Hand-Held Sound Level Meters with ICP / IEPE
Classical industrial hand-held meters with BNC / TNC
Coaxial constant current (2 mA to 4 mA) at 24 V to 28 V supply voltage Significantly better than P48: Because the DC bias voltage sits around 12 V to 14 V, a symmetrical voltage swing of approx. ±7 V to ±10 V is possible. approx. 5.0 Vrms to 7.0 Vrms (typ. 6.0 Vrms / 17.0 Vpp) 🟡 Good (Industrial)

Solid industrial standard, but still strictly requires switching to low-sensitivity 1/4" capsules above 140 dB.

View Sound Level Meter Guide →
Reference Hand-Held Sound Level Meters with LEMO
e.g., Svantek SV 979 (Laboratory Reference Handheld)
Multi-pin LEMO connector with dedicated high preamplifier supply rails (± supply & 200 V polarization) As a true laboratory reference handheld, the Svantek SV 979 powers the preamplifier with high dual-polarity supply rails without the bottleneck of P48 or single-wire IEPE. up to approx. 10.0 Vrms (140 dB+ even with standard capsule) 🔵 Excellent (Hardware Reference)

The only handheld instrument capable of handling the highest voltages directly—albeit in a very high price bracket (also available for rental).

Svantek SV 979 in Rental Pool →
Akulap Base + ATD5-T / Gefell MV 240
Our Modular PC High-SPL Solution (140 dB to 186 dB)
Direct Dual-ADC digitization inside the preamplifier (10 Vrms / 28.3 Vpp) + USB Zero analog XLR bottleneck: The preamplifier inside the ATD5-T (10 Vrms) or MV 240 (incl. 200 V generator & 192 kHz) digitizes the signal immediately with full dynamic range. Akulap Base provides Class 1 SPL, 1/3-octave analysis, and FFT on the PC. 10.0 Vrms (28.28 Vpp) without range switching 🟢 Price-Performance & Analysis Winner

Reaches up to 186 dB Peak with Adapter A 67 and 1/4" capsules incl. real-time 1/3-octave, FFT & WAV recording on PC.

Jump to Akulap Turnkey Kits →
INTERACTIVE LAB TOOL · #HIGH-SPL-SIMULATOR · CAPSULE VOLTAGE & PREAMP CLIPPING

Interactive High-SPL Voltage & Clipping Simulator (94 dB to 186 dB)

Simulate live the sound pressure in Pascals (Pa / kPa / bar), the resulting capsule output voltage (Urms & Upp), the calibration offset ΔLcal in Akulap, and the clipping behavior of XLR/P48 handhelds (3 Vrms), ICP/IEPE (6 Vrms), and ATD5-T / MV 240 / SV 979 (10 Vrms).

140 dB SPL
Practical Presets (Quick Select):
Ideal for low to high levels. At 140 dB it already produces 10.0 Vrms (28.3 Vpp)—XLR handhelds (NTi XL2/XL3, Bedrock) already clip here, whereas the ATD5-T with Akulap measures cleanly up to 140 dB!
Direct Comparison of the 3 Preamplifier Classes at Current SPL:
XLR / P48 Handheld (3.0 Vrms) OK
ICP / IEPE Handheld (6.0 Vrms) OK
Akulap + ATD5-T / MV 240 / SV 979 (10.0 Vrms) OK
Sound Pressure p_rms
200,0 Pa
0,200 kPa
Peak Sound Pressure p_peak (√2)
282,8 Pa
0,283 kPa
Capsule Voltage U_rms
10,00 Vrms
Max: 10,0 Vrms
Peak-to-Peak Voltage U_pp
28,28 Vpp
Max: 28,28 Vpp
Akulap Gain Offset ΔL_cal (vs. 50 mV/Pa)
+0,00 dB
50,0 mV/Pa
Signal-to-Noise Ratio (SNR) Above Capsule Self-Noise
+125,0 dB
3% THD: 146 dB
Live Oscilloscope: Preamplifier Output Signal vs. Clipping Limit LINEAR

Red dashed line = ±U_max,peak of the selected preamplifier. As soon as U_rms > U_max,rms, the sine wave is hard-clipped at top and bottom (flat-top clipping).

🟢 SIGNAL CHAIN IN LINEAR OPERATING RANGE (NO CLIPPING & THD < 3%)

Both the microphone capsule and the selected preamplifier operate distortion-free with clean SNR (> 10 dB). LAeq, LCpeak, 1/3-octave spectrum, and FFT can be evaluated directly in Akulap Base.

Mathematical Equations Used by the Simulator:
1. Sound Pressure in Pascals: p_rms = 20 · 10⁻⁶ Pa · 10^(Lp / 20) | p_peak = p_rms · √2
2. Capsule Output Voltage: U_rms = p_rms · (S / 1000) [V] | U_pp = U_rms · 2√2 [V]
3. Calibration Offset in Akulap: ΔL_cal = 20 · log₁₀(50 mV/Pa / S) [dB]
4. Three-Stage Check: SNR = Lp − L_noise ≥ 10 dB | U_rms ≤ U_max,rms | Lp ≤ L_max,3%THD
CAPSULE CASCADE · MICROTECH GEFELL 1/2" & 1/4" HIGH-SPL CAPSULES

High-SPL Microphone Capsules (1/4", Microtech Gefell) Technical Comparison

Below is the exact graduation of Microtech Gefell measurement capsules by sensitivity S, thermal self-noise, and maximum sound pressure level (3% THD RMS / Peak). Click the button on the right to load any capsule directly into the simulator above:

Model Size & IEC Type Polarization Sensitivity S Self-Noise Max. SPL (3% THD RMS / Peak) Frequency Range Typical Application Simulator
MK 255 / std. (Reference) MTG 311142 / #7050 1/2" Free-Field (WS2F) 200 V / 0 V (Electret) 50.0 mV/Pa 15 dB(A) 146 dB RMS / 149 dB Peak 3.5 Hz – 20 kHz Standard up to occupational safety (140 dB on 10 Vrms)
MK 301 E MTG 311138 1/4" Free-Field (WS3F) 0 V (Prepolarized) 3.5 mV/Pa 35 – 36 dB(A) 168 dB RMS / 171 dB Peak 5 Hz – 100 kHz High-SPL entry, industrial noise, ultrasound, impulses
MK 302 (200 V Variant) MTG 311127 1/4" Pressure (WS3P) 200 V (for MV 240) 3.0 mV/Pa 39 dB(A) 170 dB RMS / 172 dB Peak 5 Hz – 60 kHz Classical 200 V high-SPL measurement on MV 240
MK 341 E MTG 311156 1/4" Pressure / Boundary (WS3P) 0 V (Prepolarized) 1.4 mV/Pa 48 dB(A) 170 dB RMS / 173 dB Peak 3.5 Hz – 70 kHz Couplers, boundary surfaces, ducts, high peak pressures
MK 342 E MTG 311154 (MTG 1568) 1/4" Ultra-High-SPL Pressure (WS3P) 0 V (Prepolarized) 0.25 mV/Pa 60 dB(A) 183 dB RMS / 186 dB Peak 3.5 Hz – 70 kHz Defense, explosives, rockets, airbags (> 180 dB)
THE FUNNEL CORE · AKULAP BASE SYSTEM (INCL. 1/3-OCTAVE & FFT) & TURNKEY KITS

Akulap Base System & Modular High-SPL Turnkey Packages (140 dB / 171 dB / 186 dB)

While hand-held meters such as the NTi XL2/XL3 frequently require expensive add-on licenses for 1/3-octave analysis, FFT, or uncompressed audio recording, the Akulap Base System serves as the universal, cost-effective core of your high-SPL measurement chain:

PRIMARY FUNNEL PRODUCT · ALL-INCLUSIVE IN BASE SYSTEM

Why Akulap Base Is Unbeatable for High-SPL and Impulse Measurements

Together with the ATD5-T or Microtech Gefell MV 240, Akulap transforms your Windows PC or field laptop into a full-fledged Class 1 spectral and impulse analyzer:

Included in the Akulap Base System at No Extra Cost:
  • ✓ Standard-compliant real-time sound level meter per IEC 61672-1 Class 1 (LAeq, LCeq, LAFmax, LASmax, LAImax)
  • ✓ True peak capture LCpeak and LZpeak for impulse, blast, and occupational safety testing
  • ✓ Real-time octave and 1/3-octave band analysis per IEC 61260 included in the base system
  • ✓ High-resolution real-time FFT spectral analysis for identifying tonal components, blade-pass frequencies, and pressure pulses
  • ✓ Free sensitivity calibration for all 1/2" and 1/4" high-SPL capsules (50 mV/Pa down to 0.25 mV/Pa) plus uncompressed WAV recording
Optional Expansion Modules for Specialized High-SPL Analysis:
Optional Module: Low-Frequency Noise per DIN 45680 & DIN/TS 45610-1:2026-01

For low-frequency high-SPL emissions (1 Hz – 100 Hz) on gas turbines, power plants, industrial fans, testbeds, compressors, and marine propulsion.

Explore DIN 45680 Portal →
Optional Module: Psychoacoustics & Loudness in Sone (DIN 45631 / A1 & ISO 532-1)

For Zwicker loudness evaluation of strongly time-varying, impulsive, or high-level machinery and vehicle noise.

Explore Loudness / Sone Portal →

The 3 Pre-Configured Akulap High-SPL Turnkey Systems

Choose the appropriate stage for your maximum sound pressure level. With a single click, add all components of the turnkey bundle directly to your non-binding B2B quotation configurator:

STAGE 1 · OCCUPATIONAL SAFETY & INDUSTRY Up to 140 dB SPL (200 Pa)

Akulap Turnkey System 1: Occupational Safety & Industrial Peak SPL up to 140 dB

Akulap Base System (incl. Class 1 SPL, 1/3-octave & FFT) + ATD5-T (10 Vrms preamplifier) + 1/2" Class 1 capsule (50 mV/Pa). Outperforms XLR handhelds on workplace impulse peaks (LCpeak up to 140 dB).

• Akulap Base System (IEC 61672-1, 1/3-octave IEC 61260, FFT, WAV)
• ATD5-T USB Measurement Frontend (10.0 Vrms / 28.3 Vpp Dual-ADC)
• 1/2" Class 1 Measurement Capsule (50 mV/Pa, prepolarized)
Optionally expandable with DIN 45680 (low-frequency) & Psychoacoustics (Sone).
2075,00 € Net (2469,25 € incl. 19% VAT, excl. shipping)
STAGE 2 · IMPULSE, ULTRASOUND & TESTBEDS Up to 168 dB RMS / 171 dB Peak

Akulap Turnkey System 2: Impulse, Ultrasonic & High-SPL Signal Chain up to 168 dB (171 dB Peak)

Akulap Base System (incl. 1/3-octave & FFT) + ATD5-T (10 Vrms) + Microtech Gefell Adapter A 67 (1/4" to 1/2") + 1/4" free-field capsule Microtech Gefell MK 301 E (3.5 mV/Pa, 5 Hz to 100 kHz).

• Akulap Base System (incl. Class 1 SPL, 1/3-octave & FFT)
• ATD5-T 10 Vrms USB Frontend (optional upgrade to Gefell MV 240 for 192 kHz)
• Microtech Gefell Adapter A 67 (1/4" capsule to 1/2" preamplifier)
• Microtech Gefell MK 301 E (1/4" free-field capsule, 3.5 mV/Pa, up to 171 dB Peak)
Upgrade Tip: With MV 240 (192 kHz) you capture ultrasonic and blast spectra up to 80 kHz.
2817,00 € Net (3352,22 € incl. 19% VAT, excl. shipping)
STAGE 3 · DEFENSE, BALLISTICS, ROCKETS & AIRBAGS Up to 183 dB RMS / 186 dB Peak

Akulap Turnkey System 3: Defense, Ballistics & Rocket Reference Chain up to 183 dB (186 dB Peak)

Akulap Base System (incl. 1/3-octave & FFT) + Microtech Gefell MV 240 digital (up to 192 kHz / 80 kHz bandwidth, 0 V / 200 V switchable) + Adapter A 67 + 1/4" Ultra-High-SPL capsule MK 342 E (0.25 mV/Pa, up to 186 dB Peak).

• Akulap Base System (incl. Class 1 SPL, 1/3-octave & FFT)
• Microtech Gefell MV 240 digital (24-bit Dual-Range -> 32-bit, 192 kHz, 0 V / 200 V)
• Microtech Gefell Adapter A 67 (1/4" capsule to 1/2" preamplifier)
• Microtech Gefell MK 342 E (1/4" Ultra-High-SPL pressure capsule, 0.25 mV/Pa, up to 186 dB Peak)
Alternatively configurable with MK 341 E (1.4 mV/Pa, up to 173 dB Peak) for boundary & coupler testing.
4185,03 € Net (4980,17 € incl. 19% VAT, excl. shipping)
KEY MECHANICAL LINK · MICROTECH GEFELL ADAPTER A 67

Why Adapter A 67 (1/4" Capsule to 1/2" Preamplifier) Is Essential

Because virtually all high-SPL measurement microphone capsules (> 160 dB to 186 dB) are physically engineered as 1/4" capsules (1/4" – 60 UNS thread) for higher diaphragm stiffness, smaller active area, and resonance frequencies > 70 kHz, whereas our high-dynamic USB preamplifiers (ATD5-T and Microtech Gefell MV 240) feature a 1/2" standard thread (1/2" – 60 UNS), the precision-machined Microtech Gefell Adapter A 67 serves as the vital mechanical and coaxial link of the high-SPL signal chain.

Individual High-SPL Signal Chain Components (Catalog & Single Selection)

All software modules, 10 Vrms USB preamplifiers, thread adapters, and 1/4" high-SPL capsules can also be added individually to your quote or inspected in detail below:

FUNNEL CORE · CLASS 1 + 1/3-OCTAVE + FFT INCLUDEDArt. #3303016↗
Akulap Base System – PC Sound Level Meter, 1/3-Octave & FFT Analyzer

Akulap Base System – PC Sound Level Meter, 1/3-Octave & FFT Analyzer

Dr. Jordan Design · Art. #3303016

Standard-compliant Class 1 sound level meter (IEC 61672-1, LAeq, LCeq, LCpeak, LZpeak), real-time octave/1/3-octave analysis (IEC 61260), high-resolution FFT analyzer, WAV recording, and free sensitivity calibration (50 mV/Pa down to 0.25 mV/Pa).

Investment / List price:750,00 €net
incl. 19% VAT, excl. shipping:892,50 €
10 Vrms DUAL-ADC FRONTEND · 1/2" THREADArt. #6510↗
ATD5-T Modular 1/2" USB Measurement Frontend (10 Vrms / 28 Vpp)

ATD5-T Modular 1/2" USB Measurement Frontend (10 Vrms / 28 Vpp)

Dr. Jordan Design · Art. #6510

Handles up to 10.0 Vrms (28.3 Vpp) input voltage without range switching. Reaches 140 dB SPL with a 1/2" capsule (#7050 / MK 255); directly compatible with 0 V prepolarized 1/4" high-SPL capsules via Adapter A 67 beyond 165 dB. (Note: Ships without capsule—please pair with #7050 or 1/4" capsule + Adapter A 67).

Investment / List price:825,00 €net
incl. 19% VAT, excl. shipping:981,75 €
LAB REFERENCE · 192 kHz · 0 V / 200 V SWITCHABLEArt. #75240↗
Microtech Gefell MV 240 digital – High-End 1/2" USB Preamplifier

Microtech Gefell MV 240 digital – High-End 1/2" USB Preamplifier

Dr. Jordan Design · Art. #75240

24-bit Dual-Range Sigma-Delta ADC with 32-bit calibrated stream, 48 / 96 / 192 kHz sample rates (up to 80 kHz bandwidth for shockwaves), and internally switchable 200 V polarization voltage for all 0 V and 200 V capsules. (Ships without capsule).

Investment / List price:1963,03 €net
incl. 19% VAT, excl. shipping:2336,00 €
KEY ADAPTER · 1/4" TO 1/2" (60 UNS)Art. #MTG_302305↗
Microtech Gefell Adapter A 67 (1/4" Capsule to 1/2" Preamplifier)

Microtech Gefell Adapter A 67 (1/4" Capsule to 1/2" Preamplifier)

Dr. Jordan Design · Art. #MTG_302305

Essential mechanical and electrical adapter allowing 1/4" high-SPL capsules (MK 301 E, MK 302, MK 341 E, MK 342 E) to be mounted onto 1/2" preamplifiers ATD5-T or MV 240.

Investment / List price:264,50 €net
incl. 19% VAT, excl. shipping:314,75 €
1/4" FREE-FIELD · 3.5 mV/Pa · UP TO 168 / 171 dBArt. #MTG_311138↗
Microtech Gefell MK 301 E – 1/4" Free-Field Capsule (0 V)

Microtech Gefell MK 301 E – 1/4" Free-Field Capsule (0 V)

Dr. Jordan Design · Art. #MTG_311138

Prepolarized 1/4" free-field capsule (WS3F / Class 1), sensitivity 3.5 mV/Pa, frequency range 5 Hz to 100 kHz, self-noise 36 dB(A), max SPL 168 dB RMS / 171 dB Peak (3% THD). Ideal for industrial impulses and ultrasound.

Investment / List price:977,50 €net
incl. 19% VAT, excl. shipping:1163,22 €
1/4" PRESSURE/BOUNDARY · 1.4 mV/Pa · UP TO 170 / 173 dBArt. #MTG_311156↗
Microtech Gefell MK 341 E – 1/4" Pressure & Boundary Capsule (0 V)

Microtech Gefell MK 341 E – 1/4" Pressure & Boundary Capsule (0 V)

Dr. Jordan Design · Art. #MTG_311156

Prepolarized 1/4" pressure capsule (WS3P), sensitivity 1.4 mV/Pa, frequency range 3.5 Hz to 70 kHz, self-noise 48 dB(A), max SPL 170 dB RMS / 173 dB Peak. Optimized for couplers, ducts, and boundary measurements.

Investment / List price:977,50 €net
incl. 19% VAT, excl. shipping:1163,22 €
1/4" ULTRA-HIGH-SPL · 0.25 mV/Pa · UP TO 183 / 186 dBArt. #MTG_311154↗
Microtech Gefell MK 342 E – 1/4" Ultra-High-SPL Pressure Capsule (0 V)

Microtech Gefell MK 342 E – 1/4" Ultra-High-SPL Pressure Capsule (0 V)

Dr. Jordan Design · Art. #MTG_311154

Prepolarized 1/4" Ultra-High-SPL capsule (WS3P), sensitivity 0.25 mV/Pa, frequency range 3.5 Hz to 70 kHz, self-noise 60 dB(A), max SPL 183 dB RMS / 186 dB Peak. Built for defense, ballistics, explosives, rockets, and airbags.

Investment / List price:1207,50 €net
incl. 19% VAT, excl. shipping:1436,92 €
1/4" PRESSURE · 3.0 mV/Pa · 200 V · UP TO 172 dBArt. #MTG_311127↗
Microtech Gefell MK 302 – 1/4" Pressure Capsule (200 V)

Microtech Gefell MK 302 – 1/4" Pressure Capsule (200 V)

Dr. Jordan Design · Art. #MTG_311127

Classical 200 V polarized 1/4" pressure capsule (WS3P) for operation on the MV 240. Sensitivity 3.0 mV/Pa, frequency range 5 Hz to 60 kHz, self-noise 39 dB(A), max SPL up to 172 dB.

Investment / List price:1127,00 €net
incl. 19% VAT, excl. shipping:1341,13 €
1/2" CLASS 1 REFERENCE · 50 mV/Pa · UP TO 140 dB ON ATD5-TArt. #7050↗
1/2" Class 1 Measurement Microphone Capsule (50 mV/Pa, Prepolarized)

1/2" Class 1 Measurement Microphone Capsule (50 mV/Pa, Prepolarized)

Dr. Jordan Design · Art. #7050

Standard 1/2" free-field capsule (50 mV/Pa) as primary capsule for the ATD5-T up to 140 dB SPL (occupational safety & industry).

Investment / List price:500,00 €net
incl. 19% VAT, excl. shipping:595,00 €
OPTIONAL AKULAP MODULE · LOW-FREQ 1 Hz – 100 HzArt. #3303061↗
Akulap Low-Frequency Noise Module (DIN 45680 & DIN/TS 45610-1)

Akulap Low-Frequency Noise Module (DIN 45680 & DIN/TS 45610-1)

Dr. Jordan Design · Art. #3303061

Expands Akulap Base with standard-compliant low-frequency and infrasound rating for power plants, gas turbines, test cells, and industrial fans.

Investment / List price:1000,00 €net
incl. 19% VAT, excl. shipping:1190,00 €
OPTIONAL AKULAP MODULE · LOUDNESS IN SONEArt. #3303025↗
Akulap Psychoacoustics & Loudness in Sone Plug-in (DIN 45631 / ISO 532)

Akulap Psychoacoustics & Loudness in Sone Plug-in (DIN 45631 / ISO 532)

Dr. Jordan Design · Art. #3303025

Zwicker loudness evaluation in Sone for high-level machinery, automotive, and impulse noise.

Investment / List price:1100,00 €net
incl. 19% VAT, excl. shipping:1309,00 €
CALIBRATION & TEST LAB · 114 dB SNR RULE & APX555 CAPSULE VERIFICATION

Calibrating 1/4" High-SPL Capsules & APx555 Laboratory Verification Package

Even a 186 dB Ultra-High-SPL capsule is calibrated in the field using an acoustic sound calibrator at 1 kHz. However, two critical engineering rules apply:

FIELD TIP · WHY 114 dB INSTEAD OF 94 dB?

114 dB Calibrator Level & 1/4" Reduction Adapter (#7150) for Maximum SNR

Low-sensitivity 1/4" high-SPL capsules inherently exhibit higher thermal self-noise: 36 dB(A) on the MK 301 E, 48 dB(A) on the MK 341 E, and 60 dB(A) on the MK 342 E. If you were to calibrate an MK 342 E (0.25 mV/Pa) at 94 dB (1 Pa = 0.25 mV) in a noisy industrial or firing-range environment, the signal-to-noise ratio (SNR) would be only around 34 dB.

The Solution: Use a switchable sound level calibrator with a 114 dB setting (10 Pa)—such as our bestselling Center 326 (#7002, 94 dB / 114 dB)—paired with the precision 1/4" reduction adapter (#7150). At 114 dB you gain a full +20 dB of margin (> 54 dB SNR even on the 0.25 mV/Pa capsule) and calibrate Akulap in seconds!

DRESDEN TEST LAB · AUDIO PRECISION APX555 + SPECTRA SQ4.2

APx555 Laboratory Verification Package After Extreme Blast, Ballistic, or Impulse Tests (#S104)

Following extreme impulse, airbag, pyrotechnic, or firearm blast measurements, there is always a risk that a capsule's high-tension nickel diaphragm has suffered invisible micro-fissures, localized plastic stretching, or membrane tension loss, causing sensitivity and THD limits to drift.

In our Dresden calibration laboratory, we verify your 1/2" and 1/4" measurement microphones using the world-leading Audio Precision APx555 reference analyzer and the Spectra SQ4.2 high-SPL precision pressure chamber (up to 170 dB) for sensitivity (mV/Pa), frequency response, and total harmonic distortion (THD)—including a traceable factory calibration certificate.

RECOMMENDED · 94 dB & 114 dB SWITCHABLEArt. #7002↗
Center 326 Sound Level Calibrator (94 dB / 114 dB · 1 kHz)

Center 326 Sound Level Calibrator (94 dB / 114 dB · 1 kHz)

Dr. Jordan Design · Art. #7002

Switchable between 94 dB (1 Pa) and 114 dB (10 Pa). The 114 dB setting provides the critical +20 dB SNR margin for accurate field calibration of low-sensitivity 1/4" high-SPL capsules in Akulap.

Investment / List price:277,00 €net
incl. 19% VAT, excl. shipping:329,63 €
CALIBRATOR ADAPTER · 1/2" TO 1/4"Art. #7150↗
1/4" Reduction Adapter (#7150) for Sound Calibrators

1/4" Reduction Adapter (#7150) for Sound Calibrators

Dr. Jordan Design · Art. #7150

Adapts the 1/2" cavity of sound level calibrators (Center 326, B&K 4231, MTG 4010, Svantek) with an airtight seal to 1/4" measurement microphone capsules (MK 301 E, MK 302, MK 341 E, MK 342 E).

Investment / List price:25,00 €net
incl. 19% VAT, excl. shipping:29,75 €
LAB SERVICE · MAX-SPL & THD CHECK UP TO 170 dBArt. #S104↗
Microphone Calibration & High-SPL THD Testing up to 170 dB (#S104)

Microphone Calibration & High-SPL THD Testing up to 170 dB (#S104)

Dr. Jordan Design · Art. #S104

Laboratory verification package on the Audio Precision APx555 and Spectra SQ4.2 pressure chamber to detect diaphragm micro-cracks, tension loss, and THD drift after extreme impulse tests.

Investment / List price:Price on request
SYSTEM NETWORK · RELATED ENGINEERING PORTALS & SIMULATORS

Related Engineering Portals in the Acoustics Lab

Explore adjacent topic clusters ranging from ultra-low-noise measurements (< 15 dB(A)) and our USB and Microtech Gefell reference hubs to our calibration laboratory:

FUNNEL CORE

Sound Level Measurement with Akulap (IEC 61672)

Complete feature overview of the Akulap Base System (LAeq, LCpeak, 1/3-octave, FFT).

SELECTION GUIDE

Precision Sound Level Meters Overview

Comparison of Class 1/2 hand-held meters and PC-based measurement systems.

HANDHELD MATRIX

System Comparison: NTi XL2/XL3 vs. Bedrock vs. Akulap

Technical and economic head-to-head comparison of common acoustic analyzers.

COUNTERPART (< 15 dB)

Ultra-Low-Noise Measurement Microphones

The physical counterpart to High-SPL: measurements near the threshold of human hearing.

GEFELL HUB

Microtech Gefell Reference Microphones & Capsules

All 1/2" and 1/4" capsules, MV 240 digital, and Adapter A 67 in detail.

USB FRONTENDS

Digital USB Measurement Microphones (ATD5-T, #6533, MV 240)

Direct 24/32-bit digitization inside the microphone body without audio interfaces.

FUNDAMENTALS

Engineering Guide to Measurement Microphones (IEC 61094)

Free-field, pressure, and diffuse-field capsules, sizes (1", 1/2", 1/4"), and polarization.

LOW-FREQ MODULE

Low-Frequency Noise (DIN 45680 & DIN/TS 45610-1)

Evaluation of low-frequency pressure waves (1–100 Hz) on turbines, testbeds, and power plants.

PSYCHOACOUSTICS

Measuring Loudness in Sone (DIN 45631 & ISO 532-1)

Human-ear-adapted Zwicker loudness analysis for loud machinery and impulse noise.

CALIBRATION LAB

Microphone & Calibrator Calibration (IEC 61672 / 60942)

Traceable factory calibration, frequency response, and Max-SPL THD testing (#S104).

REFERENCE ANALYZER

Audio Precision APx555 Reference Laboratory

Inside our APx555 test bench and Spectra SQ4.2 precision pressure chamber.

CALIBRATORS

Sound Level Calibrators (94 dB / 114 dB) & Adapters

Center 326, B&K 4231, Class 1 PTB calibrators, and 1/4" reduction adapters (#7150).

ENGINEERING FAQ · FREQUENTLY ASKED QUESTIONS ON HIGH-SPL MEASUREMENT

Frequently Asked Questions (FAQ) on High-SPL Measurements (140 dB – 186 dB)

Answers to the most important physical and metrological questions from occupational safety, defense engineering, aerospace, and testbed construction:

Why does the preamplifier almost always overload before the microphone capsule at 135–140 dB? ▼

A standard 1/2" measurement microphone capsule has a sensitivity of S = 50 mV/Pa and a mechanical 3% THD limit of approx. 146 dB. At 140 dB SPL, however, the effective sound pressure is already 200 Pa. Multiplied by 50 mV/Pa, the capsule generates an output voltage of 10.0 Vrms (28.28 Vpp peak-to-peak). Classical 48 V XLR hand-held sound level meters (such as NTi XL2/XL3 or Bedrock SM50/SM90) typically handle only 2.5 Vrms to 5.0 Vrms at their XLR input stage and hard-clip the waveform long before the capsule reaches its mechanical limit. Our ATD5-T USB frontend, by contrast, handles a full 10.0 Vrms (28.3 Vpp) without clipping.

What is the difference between the 3% THD maximum SPL and the mechanical destruction limit? ▼

The maximum SPL at 3% THD (Total Harmonic Distortion) specifies the highest sound pressure level that a capsule can transduce into an electrical voltage with no more than 3% harmonic distortion (e.g., 168 dB RMS / 171 dB Peak for the Microtech Gefell MK 301 E, or 183 dB RMS / 186 dB Peak for the MK 342 E). The mechanical destruction limit typically lies 6 to 12 dB higher and merely indicates the pressure at which the nickel diaphragm is permanently deformed or torn. For valid metrological measurements, only the 3% THD limit may be used.

How do I connect a 1/4" high-SPL capsule (MK 301 E / MK 341 E / MK 342 E) to the ATD5-T or MV 240? ▼

All 1/4" high-SPL capsules from Microtech Gefell feature a 1/4"-60 UNS fine thread, while the ATD5-T and MV 240 preamplifiers feature a 1/2"-60 UNS thread. Using the precision-machined Microtech Gefell Adapter A 67 (SKU MTG 302305), any 1/4" capsule threads mechanically and electrically onto the 1/2" preamplifier. Prepolarized 0 V capsules (MK 301 E, MK 341 E, MK 342 E) operate on both the ATD5-T and MV 240; classical 200 V capsules (such as the MK 302) operate on the MV 240 with its internal 200 V polarization enabled.

Are octave/1/3-octave analysis and FFT already included in the Akulap Base System? ▼

Yes! Unlike many hand-held sound level meters where 1/3-octave filters, FFT, or WAV recording must be unlocked as costly individual options, the Akulap Base System (#3303016) already includes the full Class 1 sound level meter per IEC 61672-1 (incl. LCpeak and LZpeak), real-time octave and 1/3-octave band analysis per IEC 61260, the high-resolution FFT spectrum analyzer, and uncompressed WAV recording. For specialized applications, the DIN 45680 (low-frequency noise) and Psychoacoustics (Zwicker loudness in Sone) modules can be added optionally.

Why should a low-sensitivity 1/4" capsule (e.g., MK 342 E) be calibrated at 114 dB instead of 94 dB? ▼

Due to its ultra-stiff diaphragm, a 186 dB capsule like the MK 342 E (0.25 mV/Pa) has a thermal self-noise of approx. 60 dB(A). With a 94 dB calibrator tone, the margin above self-noise is only 34 dB—ambient noise at the test site can easily skew calibration. By switching the calibrator (e.g., Center 326 #7002 with 1/4" adapter #7150) to 114 dB (10 Pa), the signal-to-noise ratio increases to over 54 dB SNR, guaranteeing a highly accurate level calibration in Akulap.

How can I tell after a blast or ballistic test whether the microphone capsule was damaged? ▼

A simple 1 kHz field calibrator check is often insufficient after extreme shockwaves, because micro-fissures or diaphragm tension loss first manifest as a shift in resonance frequency or a sharp rise in total harmonic distortion (THD) at high levels. With our Laboratory Verification Package (#S104), we test your capsule in our Dresden lab on the Audio Precision APx555 and inside the Spectra SQ4.2 precision pressure chamber up to 170 dB for frequency response, sensitivity, and THD.